ECG ki monitè kè bebe se yon enstriman otomatik ak entèlijan, ki se sitou itilize kontwole paramèt fizik pasyan yo epi li jwe yon wòl enpòtan nan asire sekirite lavi pasyan ki grav malad. Monitè ECG a se tou ekipman elektwonik yo itilize nan depatman an ak pi gwo kantite nan lopital la. Anplwaye medikal yo ta dwe peye atansyon sou itilizasyon chak jou, antretyen ak dezenfeksyon pou fè machin nan rive nan pi bon kondisyon travay la.
Prekosyon:
01. Pousyè
Divès eleman optik nan enstriman an, kèk switch, chòk elektrik, elatriye, yo ta dwe kenbe pwòp souvan. Anplis de sa, depi manchèt NBP la mare nan pasyan an pou yon tan long, li bezwen netwaye regilyèman pou retire odè a sou manchèt la, espesyalman pou kèk pasyan ki gen senyen ak vomisman.
02. Imidite-prèv
Konpozan optoelektwonik yo ak eleman elektwonik nan enstriman an gen tandans fè kanni ak domaj apre yo fin afekte pa imidite. Se poutèt sa, li nesesè yo kòmanse machin nan regilyèman tcheke ak ranplase desiccant la nan tan. Sa a se aktyèlman menm jan ak aparèy nan kay la nan kay la. Lè li pa itilize pou yon tan long, li ta dwe limen regilyèman pou elimine imidite ak reyalize objektif imidite-prèv. Pandan sezon an Huangmei, move tan an se pi mouye a, kidonk ou ta dwe peye plis atansyon.
03, pwoteksyon chalè
Enstriman elektwonik ki gen gwo -presizyon yo relativman delika, epi yon tanperati ki twò wo oswa twò ba pral afekte operasyon nòmal li. Monitè jeneralman mande pou anviwònman travay ak depo apwopriye ak ti fluctuations tanperati, kidonk li jeneralman pi bon pou konfigirasyon yon regilatè tanperati. Anjeneral, li pi apwopriye pou kenbe tanperati a nan 20 degre 25 degre. Anplis de sa, li oblije kenbe lwen sous chalè tankou ekipman terapi enfrawouj, epi evite limyè solèy la dirèk.
04. Anti-Vibration
Vibwasyon pa pral sèlman afekte pèfòmans ak rezilta mezi monitè a, men tou, lakòz domaj nan kèk eleman presizyon, kidonk li oblije mete enstriman an sou yon workbench oswa Vibration -amortissement tab lwen sous la Vibration.
05. Anti-kowozyon
Pandan itilizasyon ak depo enstriman an, evite kontak ak anviwònman an ak gaz korozif ak likid tankou asid ak alkali, konsa yo anpeche eleman yo pa domaje pa ewozyon.
Tcheke anvan ou itilize
♥The environment and power supply meet the requirements.
♥The case of the monitor is clean and free of smudges.
♥The shell, buttons, knobs, interfaces and accessories have no mechanical damage.
♥The power cord has no abrasion and good insulation performance.
♥The ground wire is connected correctly.
♥ Use only specified accessories such as electrodes, sensors and probes.
♥ The clock of the monitor is correct.
♥ Sound alarm and light alarm function normally.
♥ The recorder works normally and the recording paper meets the specified requirements.
♥ Check the performance of the battery.
♥Various monitoring functions of the system are in good working condition.
netwaye ak dezenfekte
01. Etap netwayaj:
Turn off the monitor and disconnect the AC power → Clean the outside of the main unit → Clean the display screen → Clean the cables and sensors → Wipe the cleaned part with a dry cloth or air dry → If there is contamination by patient secretions, use chlorine Wipe with disinfectant, then wipe with water to dry → place the device in a ventilated and cool environment to air dry.
02. Metòd netwayaj ekstèn nan lame a:
Yo ta dwe itilize yon twal pwòp, mou, eponj oswa koton pou absòbe ajan netwayaj ki pa-agresif, tòde byen epi siye dousman. Ajan netwayaj opsyonèl: Dilye dlo savon, amonyak dilye, ipoklorit sodyòm (poud blanchi pou lave), oswa fòmaldeyid (3537 pousan), oksijene idwojèn (3 pousan), 70 pousan etanòl, 70 pousan izopropanol. Siye sèk ak yon twal pwòp sèk.
03. Montre metòd netwayaj:
Siye ak 75 pousan alkòl boul koton chak semèn. Siye ekspozisyon an ak 10 pousan klowòks oswa dilye dlo savon. Siye sèk ak yon twal pwòp sèk.
04. Ki jan yo netwaye kab la:
♥Please wipe the outer surface of the cable with 75 percent alcohol, be careful not to let the liquid flow into the cable connector. Also do not immerse in liquids.
♥ If there is any residue such as tape on the wire, it should be wiped with tape remover and then disinfected.
♥ Air dry or clean with a clean, dry cloth.
♥The wires that are too long can be bent into larger circles and tied up and fixed for ease of use. Disposable parts must be discarded and not ready for reuse after washing.
♥During backup, each lead wire and connecting tube should be bundled and fixed separately, and placed in a plastic bag or cloth bag to keep it clean and tidy, so that it can be used again.
05. Netwayaj metòd sond oksijèn san:
♥ Remove the sensor from the patient and from the monitor.
♥Please wipe the sensor with 75 percent alcohol, then dry it with a dry cloth. (It can also be used to clean the light-emitting and receiving parts.) Be careful not to let liquid flow into the cable socket. Also do not immerse in liquids.
♥ Clean the rest of the same cable.
06. Netwayaj metòd manchèt:
♥The cuff cannot be dry cleaned, but it can be machine washed or hand washed, and hand washing can prolong the life of use. Before washing, the rubber bag should be removed. After washing, wait for the sleeve to dry before repacking the rubber bag.
♥The sleeve can be sterilized by conventional methods, such as: autoclaving, gas or radiation sterilization, sterilization by immersion in decontamination solution. (Now replace the cuff twice a week and send it to the supply room for disinfection).
♥(For special infection treatment) Soak the cuff in 0.5g/L chlorine-containing disinfectant (or 75 percent alcohol) for 30 minutes, then rinse it with clean water and dry it in the air for later use.
antretyen
♥The monitor should be placed in a ventilated and dry place.
♥Connect the purification power supply to maintain the voltage (220±22)V, reduce the use with high-power electrical appliances.
♥ Before cleaning and sterilizing the monitor, turn off the monitor and disconnect the AC power supply at the same time.
♥ When arranging accessories, do not fold the lines, but wrap them in a circle to avoid breaking.
♥Do not perform high temperature, high pressure and immersion disinfection on the ECG monitor and accessories, and avoid contact with corrosive gases and liquids such as acid and alkali. Never immerse any part of the system in liquid. If liquid is accidentally spilled on the monitor, it should be wiped with a dry cloth immediately. Do not let liquid flow into the monitor. Personnel overhaul.
♥Avoid frequent switching on and off of the instrument. When the patient only suspends the instrument for a long time, just remove the monitoring electrode buckle, and it is not necessary to turn off the instrument. If you see signs of deterioration or damage to the cable, replace the cable and do not use it for patient monitoring.
♥Be careful not to fold the hose connecting the cuff, it is easy to be damaged when folded for a long time.
♥ When the printed ECG bands are too light or inconsistent in shades, clean the surface of the print head with a cotton ball dipped in alcohol to remove the remaining paper scraps.
♥The staff wash their hands and trim their nails before operation, so as not to damage the touch buttons or the screen.
♥At least 5CM space should be reserved around the monitoring instrument in use to ensure the circulation of air and achieve good heat dissipation effect. The monitor in the standby state should be placed in a ventilated and dry place to avoid moisture, and should be charged regularly, usually once a week, and checked, cleaned and maintained; it should be kept by a special person.
♥ Regularly conduct stability tests on the monitoring indicators of the monitor and keep the qualified records.