Portable koulè Doppler ultrason

Portable koulè Doppler ultrason

High-end Full Digital pòtab koulè Doppler Ultrason C onfiguration: 1)Full-Digital 2D gri echèl D 2)Full-Digital Tissus Harmonic Imaging (THI) 3)Koulè Doppler D koule san 4)Direksyon koulè enèji Doppler D 5)P Doppler D (PW) 6) Doppler Onn Kontinyèl...
Voye rechèch
Chat kounye a
Dekri teren
Karakteristik teknik

High-end Full Digital pòtab koulè Doppler ultrason

Portable Color Doppler Ultrasound

 

Konfigirasyon:

 

1)Full-Digital 2D gri echèl D

2)Full-Digital Tissus Harmonik Imaging (THI)

3) D 'koulè Doppler sikilasyon san

4)Direksyon koulè enèji Doppler D

5) D' Pulse Wave Doppler (PW)

6) D' kontinyèl vag Doppler (CW)

7) D 'espas konpoze

8) D' trapezoidal

9)2D, koulè, Doppler mòd otomatik ajisteman optimize teknoloji

10) Triple senkronizasyon an tan reyèl

11) Teknoloji adapte pou elimine tachte

12) Imaj 3D an tan reyèl

13) Entelijan imaj - nan - mòd imaj imaj (PIP)

14)Monitè: 15 pous segondè rezolisyon medikal LCD monitè, ang reglabl

15)Konektè sonde: Pi gwo pase oswa egal a 2 aktif

C90 with convex and 4D probe_副本

Aplikasyon:

nan vant, uroloji, OB & GYN, pedyatri / neonatal, supèrfisyèl / ti ògàn, miskiloskeletal, kadyoloji elatriye.



Konfigirasyon sond miltip:

1.1 Konvèks frekans sond: 2.0-5.0MHZ(milti-frekans, frekans Harmonik pi gran pase oswa egal a 5), ang optik pwofonde 20 degre -85 degre, vizib ak reglabl.

1.2 Frekans sond lineyè: 6.0-12.0MHZ(milti-frekans, frekans Harmony Pi gran pase oswa egal a 4), optik sonde ak teknoloji D trapezoidal ak teknoloji defleksyon gwo bout bwa 2D

1.3 Frekans sond trans-vajen: 5.0-9.0MHZ (milti-frekans, frekans amonik Pi gran pase oswa egal a 2 ), ang eskanè sonde 20 degre -160 degre, vizib ak reglabl.

1.4 Tan reyèl 3D (4D) volim sonde frekans: 2.0-6.0MHz, 4 segments milti-frekans.

1.5 Etalaj pwofonde frekans sond: 2.5-4.0MHz, 3 segments milti-frekans.

YJ-C90_副本YJ-C90  (3)

Baj popilè: Portable koulè Doppler ultrason

1.1 Konvèks frekans sond: 2.0-5.0MHZ(milti-frekans, frekans Harmonik pi gran pase oswa egal a 5), ang optik pwofonde 20 degre -85 degre, vizib ak reglabl.

1.2 Frekans sond lineyè: 6.0-12.0MHZ(milti-frekans, frekans Harmony Pi gran pase oswa egal a 4), optik sonde ak teknoloji D trapezoidal ak teknoloji defleksyon gwo bout bwa 2D

1.3 Frekans sond trans-vajen: 5.0-9.0MHZ (milti-frekans, frekans amonik Pi gran pase oswa egal a 2 ), ang eskanè sonde 20 degre -160 degre, vizib ak reglabl.

1.4 Tan reyèl 3D (4D) volim sonde frekans: 2.0-6.0MHz, 4 segments milti-frekans.

1.5 Etalaj pwofonde frekans sond: 2.5-4.0MHz, 3 segments milti-frekans.