Pwisan PC ak 3D Ultrason machin

Pwisan PC ak 3D Ultrason machin

3D Notebook Koulè Ultrason Scanner ansyen YJ-U60 se konplètman pataje sèvis ak bon jan kalite imaj akseptab nan yon sistèm pòtab ultrason. Kontrèman ak lòt sistèm mitan pòtab, YJ-U60 sipòte tan reyèl 4D, pedyatrik TEE, de pò aktif ak operasyon batri. Karakteristik: ...
Voye rechèch
Chat kounye a
Dekri teren
Karakteristik teknik

3D Notebook Koulè Ultrason Scanner

Powerful PC and 3D Ultrasonic Machine

Forermed YJ-U60 se konplètman pataje sèvis ak bon jan kalite imaj akseptab nan yon sistèm pòtab ultrason. Kontrèman ak lòt sistèm mitan pòtab, YJ-U60 sipòte tan reyèl 4D, pedyatrik TEE, de pò aktif ak operasyon batri.

Karakteristik:

Imaj pwisan

- FSI™ (plen Spectrum Imaj)

- SRF™ (Filtè Rediksyon Speckle)

- Harmonic Imaj / Batman kè Inversion Harmonic Imajinasyon

- Rapidman™

Konsepsyon kontra enfòmèl ant

1.Full-Chin an tap Travay

- Rakoursi ak fonksyonèl gwoup kle

- Mòd kanpe pou bòt rapid-up

- Meni Thumbnail

- DICOM 3.0 konpatib ranpli imaj

- Rapidman™

- Cine sove - jwe

2. Sistèm Achitekti Sistèm Optimize

- Konsepsyon kontra enfòmèl ant pou manevwe segondè

- Wide gade 15 pous LCD kontwole

- 2 pò sondaj (si ou ipsyonèl)

- Pote manch

- 3 pò USB

- 4 wou machin balanse

3. Konsepsyon zanmitay zanmitay

- Customizable mezi pake ak makè kò

- Manadjè depo

- Backlit kontwòl kle ak klavye QWERTY

Imaj YJ-U60 APLIKASYON KLINIK PLEN:

1.3D/4D imajinasyon;

2. Souch materyèl;

3. Gratis-men 3D;

4.3D-PW;

5. Anatomic Mòd;

6. Trapezoid Imaging;

7. WFOV;

8. Koulè koulè imaj;

9. CW;

10. Pouvwa / Direksyon pouvwa Dopler;

11. Oto IMT Mezi;

12. TDI;

13. THI;

14. Tan reyèl Triplex;

Mezi ak kalkil:

1. OB: HR, Velocity (D), Aksè, Auto Trace, Pwen tras, RI, SI, M Trace (L), M Trace (H), Velocity (C), CRL, BPD, HC, AC, FL, OFD, HL, GS, Radyus, Ulna, Tibi, Fibula, N.B.L, AFI ...

2. Radyoloji: Pik Sys, Pik Dys, vle di, Tan, HR, Velocity (D), Aksè, Oto Trace, Pwen tras, RI, SI, M Trace (L), M Trace(H), Koule Velokity, D koule, T koule, Lt. Renney, Rt. Kidney, IMT ....

3. Kadyak: AR, LVOP, TR, PUL. VALV, BATMAN KÈ. VENIN, RV, BF, LVET, Tan, HR, Tras oto, Pwen tras, LAD / AOD, MPAD, RVED, RVEDS, LVM, BSA (Input), HR (Input).....

4. Vaskilè: VFD, VFA, Tan, HR, Vis (D), Aksè, Auto Trace, Pwen Tras, RI, SI, M Trace (L), M Trace (H), Velocity (C), IMT, %DST, %AST, Dist, Zòn, Ellipse, Kwa, Ang, Dist Ratio ......

5. GYN: Uterine, Cervix, UT_L/CX_L, Lt.Ovary, Rt.Ovary, Ando L, DO Follicle, Kò Matris, Dist, Zòn, Ellipse, Kwa, Ang, Dist Rat, Para, M Trace (L), M Trace (H).....

6. Ti Pati: HR, Aksè, Velocity (D), Oto Trace, Pwen tras, RI, SI, M Trace (L), M Trace (H), Dist, Rt.Thyroid, Lt.Thyroid, Zòn, Ellipse, Ang, Para, Rapò Distans, Distans .....

7. Urology: Lt.AG, Lt.AG, Lt.Testicle, Lt.Testicle, Lt.Sperm, Lt.Sperm, Rud.Urine, Pwostat, Tras oto, Pwen tras, Aksè, HR, RI, SI, Dyamèt, Joint Angle ....

Baj popilè: PC ak 3D machin ultrasonik, Lachin, Swèd, manifaktirè, faktori, pri ki ba